Search This Blog

Radio Guy Tees

Radio Guy Tees
Radio Guy T-Shirts

Wednesday, 25 November 2026

Is Your LM2596 Really an LM2596?

A Simple Test for Suspect Buck Converters

During the development of a power supply for my 144 MHz and 432 MHz masthead preamplifiers, I spent some time experimenting with the inexpensive DC-DC buck converter modules that are widely available online. These particular modules were fitted with what appeared to be LM2596 adjustable voltage regulators.

Whilst investigating the noise generated by one of these modules, I discovered something rather interesting. The switching frequency was approximately 55 kHz. According to the manufacturer's datasheet, the LM2596 has a nominal switching frequency of 150 kHz.

Something clearly wasn't quite right!

Replacing the IC

Rather than consigning the module to the bin, I obtained some onsemi LM2596-ADJ devices from a reputable component supplier and replaced the IC on the existing PCB. All the other components remained unchanged.


Figure 1: The DC-DC converter module following replacement of the LM2596-ADJ.

With the modified module powered up, I connected an oscilloscope to pin 2 of the LM2596, which is the switching node connected to the inductor and Schottky diode.

The measured switching frequency was now 150 kHz, exactly as expected.

Interestingly, the older LM2576 regulator operates at a nominal switching frequency of 52 kHz. Whilst the original device may have contained silicon based on this or a similar design, there is no way of establishing that from the switching frequency alone.

Some basic performance measurements

Having established that the replacement device was operating at the correct frequency, I set about making some basic measurements with a nominal 12 V input and an output adjusted to approximately 5 V.

The results were as follows:

Load current (mA) Output voltage (V) Input current (mA) Efficiency
0 5.065 9.02 N/A
50 5.031 37.5 55.9%
100 5.011 64.2 65.0%
250 4.977 141.8 73.1%
500 4.972 273 75.9%
1000 4.960 578 71.5%

The output voltage fell by just 105 mV between no load and a load current of 1 A. Between 250 mA and 1 A, the variation was only 17 mV.

The efficiency figures are calculated assuming a constant 12 V at the module input. Whilst the efficiency is not particularly impressive by modern switching regulator standards, the module is clearly functional following replacement of the IC.


Figure 2: Calculated conversion efficiency against output load current.

Testing your own modules

If you have some of these LM2596 modules in your component collection, it might be worth spending a few minutes checking them.

Connect a suitable DC supply, adjust the output to 5 V and apply a modest load. Using an oscilloscope with a ×10 probe, measure the switching waveform at pin 2 of the regulator, with the probe ground connected to the module's ground.

Under normal operating conditions, you should see a switching frequency close to 150 kHz, corresponding to a period of approximately 6.67 µs. The onsemi datasheet specifies a frequency range of 135 to 165 kHz at a junction temperature of 25°C.

Conclusions

Whilst a switching frequency measurement cannot conclusively establish the authenticity of a semiconductor device, the difference between 55 kHz and 150 kHz is far too large to be explained by normal manufacturing tolerances.

The fact that replacing just the IC corrected the switching frequency provides fairly compelling evidence that the original component was not operating to the LM2596 specification.

Of course, none of this establishes how electrically quiet the modified module is, particularly when used in proximity to sensitive amateur radio receiving equipment. That is perhaps an experiment for another day.

It does, however, serve as a useful reminder that the markings on a semiconductor package are not necessarily a guarantee of what is inside!

References

73, G0MGX